Fluke 754 Documenting Process Calibrator-HART

FOB Reference Price:Get Latest Price
US $7,599-7,699 / Pieces | 1 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
United States
Brand Name:
FLUKE
Model Number:
Fluke 754
Measuring Current Range:
30uA
Measuring Voltage Range:
300V
Measuring Resistance Range:
10kohm
Operating Temperature:
-10 °C to +50 °C
Dimensions:
136 x 245 x 63 mm
Voltage DC Source ouput:
10.000mV/1.0000V/15.000V
Current DC Source ouput:
22.000mA
Resistance Source ouput:
10.000 ohm/100.00 ohm/1.0000kohm/10.000kohm
Frequecny Source ouput:
0.1HZ~ 50.000KHZ
SupplyAbility
SupplyAbility:
60 Piece/Pieces per Month
Packaging & Delivery
Port
Shenzhen
Lead Time :
Shipped in 2 days after payment

Fluke 754 Documenting Process Calibrator-HART:

The 754 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis. The 754 also features a powerful built in HART® interface capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.

 

 

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Holds up to a full week of downloaded procedures and calibration results.
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white dual display. Read both sourced and measured parameters simultaneously.
  • Multi lingual interface
  • Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
  • Delivered with DPC/Track Sample software.
  • Compatible with many Asset Management software packages.

 HART Capabilities :

 

The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers the communication capabilities of the 375 HART communicator

  • Requires no external box or second tool for everyday HART calibration and maintenance.
  • Offers fast HART communication.
  • Supports popular models of HART transmitters, with more devise-specific command support than any other HART field calibrator.
  • Works with multiple masters, burst mode, and multi-drop configurations.
  • Is easy to update as additional instruments are added and new HART versions are released.
  • Interrogate to determine device type, manufacturer, model, tag.
  • Reconfigure the sensor mapping of dual sensor temperature transmitters.
  • Read HART PV function and smart transmitter digital output while measuring analog mA output.
  • Read and write HART configuration functions to make field adjustments to PV range points, damping, and other top-level configuration settings.
  • Re-label smart transmitters by reading and writing to the HART tag field.

Measurement Accuracy :

Voltage DC
 1 Year2 Years
100.000 mV0.02%+0.005 mV0.03%+0.005 mV
3.00000 V0.02%+0.00005 V0.03%+0.00005 V
30.0000 V0.02%+0.0005 V0.03%+0.0005 V
300.00 V0.05%+0.05 V0.07%+0.05 V
Voltage AC
Range
40 to 500 Hz
Resolution1 Year2 Years
3.000 V0.001 V0.5%+0.002 V1.0%+0.004 V
30.00 V0.01 V0.5%+0.02 V1.0%+0.04 V
300.0 V0.1 V0.5%+0.2 V1.0%+0.2 V
Current DC
 1 Year2 Years
30.000 mA0.01% + 5 uA0.015%+7 uA
110.00 mA0.01% + 20 uA0.015%+30 uA
Resistance
 1 Year2 Years
10.000 Ω0.05% + 50 mΩ0.07%+70 mΩ
100.00 Ω0.05% + 50 mΩ0.07%+70 mΩ
1.0000 kΩ0.05% + 500 mΩ0.07%+0.5 Ω
10.000 kΩ0.1% + 10 Ω0.15%+15 Ω
Frequency
 ResolutionAccuracy (2 Years)
1.00 to 110.00 Hz0.01 Hz0.05 Hz
110.1 to 1100.0 Hz0.1 Hz0.5 Hz
1.101 to 11.000 kHz0.001 kHz0.005 kHz
11.01 to 50.00 kHz0.01 kHz0.05 kHz

 

Source Accuracy
Voltage DC
 1 Year2 Years
100.000 mV0.01%+0.005 mV0.015%+0.005 mV
1.00000 V0.01%+0.00005 V0.015%+0.0005 V
15.0000 V0.01%+0.0005 V0.015%+0.0005 V
Current DC
 1 Year2 Years
22.000 mA (Source)0.01%+ 0.003 mA0.02%+ 0.003 mA
Current Sink (Simulate)0.02% + 0.007 mA0.04% + 0.007 mA
Resistance
 1 Year2 Years
10.000 Ω0.01% + 10 mΩ0.015% + 15 mΩ
100.00 Ω0.01% + 20 mΩ0.015% + 30 mΩ
1.0000 kΩ0.02% + 0.2 Ω0.03% + 0.3 Ω
10.000 kΩ0.02% + 3 Ω0.03% + 5 Ω
Frequency
 2 Years
0.1 to 10.99 Hz0.01 Hz
0.01 to 10.99 Hz0.01 Hz
11.00 to 109.99 Hz0.1 Hz
110.0 to 1099.9 Hz0.1 Hz
1.100 to 21.999 kHz0.002 kHz
22.000 to 50.000 kHz0.005 kHz

 

Technical Data
Data Log Functions
Measure functions:Voltage, current, resistance, frequency, temperature, pressure
Reading rate:1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions:Voltage, current, resistance, frequency, temperature
Rate:4 steps/second
Trip detect:Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:Selectable, 26 V
Accuracy:10%, 18 V minimum at 22 mA
Maximum current:25 mA, short circuit protected
Maximum input voltage:50 V DC
Step Functions
Source FunctionsVoltage, current, resistance, frequency, temperature
Manual StepSelectable step, change with arrow buttons
AutostepFully programmable for function, start delay, stepvalue, time per step, repeat

 

 

 

 

 

 

 

 

 

 

 

 